Electrochemical Immunosensor for Detection of CCR4 Cancer Biomarker in Human Serum: An Alternative Strategy for Modification of Disposable ITO Electrode
Özet
Herein, a new strategy for the fabrication of a sensitive immunosensor capable of determination of CC Chemokine receptor 4 (CCR4) in complex serum samples is developed through the polymer modification on the disposable indium tin oxide electrode. Anti-CCR4 antibodies, which are utilized as sensing biomolecules, are covalently attached on the succinimide groups of polypyrrole polymer (PPyr-CSsg). The constructed immunosensor illustrates promising performances for the quantification of CCR4 antigen, with a linear detection range of 0.024–12 pg mL?1 and a low detection limit of 7.3 fg mL?1, calculated at a signal-to-noise ratio of 3. In addition, the impedimetric immunosensor displays a very successful analytical performance in terms of sensitivity, selectivity, repeatability, reproducibility, and long-term stability as well as successful applicability for the accurate quantification of CCR4 in human serum samples. The constructed immunosensor is successfully used for quantification of CCR4 antigen in human serums. In addition, the immunosensor displays only 27.54% loss in its initial signal after nine weeks storage at 4 °C. Moreover, the fabricated immunosensor is economical, highly sensitive, and selective for CCR4 antigen detection, and suitable for potential application in clinical diagnosis. © 2020 Wiley-VCH GmbH
Cilt
21Sayı
2İlgili Öğeler
Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.
-
A Highly Selective Poly(thiophene)-graft-Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum
Aydın, Muhammet; Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Wiley-VCH Verlag, 2019)In this study, an impedimetric immunosensor based on polymer poly(thiophene)-graft-poly(methacrylamide) polymer (P(Thi-g-MAm)) modified indium tin oxide (ITO) electrode is developed for the detection of the Neuron Specific ... -
A sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
Aydın, Muhammet (Elsevier Ltd, 2019)A highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide ... -
A novel electrochemical immunosensor based on acetylene black/epoxy-substituted-polypyrrole polymer composite for the highly sensitive and selective detection of interleukin 6
Aydın, Elif Burcu; Aydın, Muhammet; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2021)An ultrasensitive immunosensor based on acetylene black (AB)/epoxy-substituted-poly(pyrrole) polymer (EpxS-PPyr) composite coated disposable indium tin oxide (ITO) electrode was fabricated for interleukin 6 (IL 6) detection. ...