dc.description.abstractAim: The study aimed to compare the radiation doses absorbed by the patient in first-time percutaneous nephrostomy under computed tomography (CT) and nephrostomy replacement under fluoroscopy. Material and Methods: Eighty-nine hydronephrotic patients referred for nephrostomy were included in this retrospective study. Seventy-five of these patients had the nephrostomy for the first-time under CT- guidance. Fourteen patients had the nephrostomy replacement operation under fluoroscopy guidance. Absorbed radiation doses were compared between these operations. Results: The groups showed no statistically significant differences in means of demography (age, sex, and pathology) and operational parameters (intervention side and complications) except the absorbed radiation dose. The median effective radiation doses were 1.18 mSv and 1.68 mSv for CT and fluoroscopy, respectively. The first-time nephrostomy operations under CT were completed with radiation doses significantly lower than those in nephrostomy replacement under fluoroscopy (p < 0.001). Conclusion: Ultra-low-dose and fast-acting CT-guided nephrostomy is a safe, user-friendly procedure that leads patients to less radiation exposure than expected.en_US
dc.language.isoengen_US
dc.identifier.doi10.29058/mjwbs.852206
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectComputed tomographyen_US
dc.subjectFluoroscopyen_US
dc.subjectHydronephrosisen_US
dc.subjectNephrostomyen_US
dc.subjectRadiation doseBilgisayarlı tomografien_US
dc.subjectFloroskopien_US
dc.subjectHidronefrozen_US
dc.subjectNefrostomien_US
dc.subjectRadyasyon dozuen_US
dc.titleA Retrospective Comparison of Computed Tomography and Fluoroscopic Guided Percutaneous Nephrostomy for Evaluating Radiation Exposureen_US
dc.typearticleen_US
dc.relation.ispartofBatı Karadeniz Tıp Dergisien_US
dc.departmentFakülteler, Çorlu Mühendislik Fakültesi, Biyomedikal Mühendisliği Bölümüen_US
dc.identifier.volume5en_US
dc.identifier.issue2en_US
dc.identifier.startpage166en_US
dc.identifier.endpage172en_US
dc.institutionauthorTürk, Yaşar
dc.institutionauthorDevecioğlu, İsmail
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.trdizinid1109784en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster