Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDiken, B.
dc.contributor.authorKayışoğlu, Birol
dc.date.accessioned2023-04-20T08:05:56Z
dc.date.available2023-04-20T08:05:56Z
dc.date.issued2022
dc.identifier.issn1302-7050
dc.identifier.urihttps://doi.org/10.33462/jotaf.058491
dc.identifier.urihttps://hdl.handle.net/20.500.11776/11109
dc.description.abstractAs a result of the rapid decrease in fossil fuels and increasing energy demand, countries have turned to alternative energy sources. Renewable resources, which are alternative to fossil resources and are environmentally friendly, are clean and inexhaustible energy resources. Solar energy is one of these alternative energy sources This study; With the RetScreen program, it is aimed to analyze the suitability of the system and observe its performance before the PV system is installed. Features affecting the performance of PV systems; It has been designed by considering factors such as the position of the panel, the angle of inclination, shading and panel type. Shadow analysis was performed with the Helioscope program. In the shadow analysis, firstly, the geographical location is defined and the determined parameters are entered into the system. Technical, energy and economic analysis of the 14 kW solar system for the Ziraatbiyotek building was made. The analysis was made in 2 different scenarios and the positive and negative aspects of the solar system to be installed in the building were revealed. The Ziraatbiyotek building, where the study was carried out, was established in the Naip District of the Süleymanpaşa district of Tekirdağ province. For the Ziraatbiyotek laboratory building, 60 panels of the GES power plant with an area of 405 m2 were used. The brand of the selected panel is Astronergy Solar and each has a power capacity of 240 W. The panel inclination is 300 and the azimuth angle is 00 in the RetScreen program. Polycrystalline was used as the panel type in two different scenarios. In the first scenario, emission reduction support was not included and the payback period of the system was 10.4 years, and in the other, $15 tCO2-1 and annual support of $142 were included and the payback period of the system was 9.8 years. According to the results obtained with the program, 20.1 Wh energy produced by the solar panel system decreased 9.5 tCO2 greenhouse gas emissions. It has been obtained that if a 14 kW solar energy system is installed in the Ziraatbiyotek building, approximately 40% of the annual electricity need will be met from solar energy. © Bu çalışma Tekirdağ Namık Kemal Üniversitesi tarafından.en_US
dc.language.isoturen_US
dc.publisherNamik Kemal University - Agricultural Facultyen_US
dc.identifier.doi10.33462/jotaf.058491
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGreenhouse gasen_US
dc.subjectHelioscopeen_US
dc.subjectPV systemen_US
dc.subjectRetScreenen_US
dc.subjectZiraatbiyoteken_US
dc.titleFeasibility Study of Photovoltaic System that can be Applied to Tekirdağ Namık Kemal University Ziraatbiyotek Building using RetScreen Programen_US
dc.title.alternativeRetScreen Programı Kullanılarak Tekirdağ Namık Kemal Üniversitesi Ziraatbiyotek Binasına Uygulanabilecek Fotovoltaik Tasarımın Fizibilite Analizien_US
dc.typearticleen_US
dc.relation.ispartofJournal of Tekirdag Agricultural Facultyen_US
dc.departmentFakülteler, Ziraat Fakültesi, Biyosistem Mühendisliği Bölümüen_US
dc.identifier.volume19en_US
dc.identifier.issue3en_US
dc.identifier.startpage656en_US
dc.identifier.endpage667en_US
dc.institutionauthorKayışoğlu, Birol
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid57215436002
dc.authorscopusid14119898600
dc.identifier.scopus2-s2.0-85139788698en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster