Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorKulualp, Kadri
dc.contributor.authorYurdakul, İbrahim
dc.contributor.authorErol, Hanifi
dc.contributor.authorAtalan, Gültekin
dc.contributor.authorKılıç, Servet
dc.date.accessioned2022-05-11T14:42:13Z
dc.date.available2022-05-11T14:42:13Z
dc.date.issued2018
dc.identifier.issn0025-8628
dc.identifier.urihttps://doi.org/10.21521/mw.6024
dc.identifier.urihttps://hdl.handle.net/20.500.11776/9289
dc.description.abstractThe current study was undertaken to establish reference values of intraocular pressure in clinically normal Turkish Shepherd Dogs with the rebound tonometer (TonoVet (R)) and the applanation tonometer (Tono-Pen Vet (R)). Twenty-eight dogs (14 male and 14 female, aged 9 months-9 years, 56 eyes) were used in this study. All animals were healthy and showed no abnormalities in ophthalmic examinations, which consisted of the Schirmer tear test, slit lamp bio-microscopy, and fluorescein staining. The animals were restrained manually without using systemic anesthetics or tranquilizers. IOP was measured in both eyes with a TonoVet (R) and a Tono-Pen Vet (R). In normal dogs, the mean IOP values for all eyes were 17.63 +/- 3.34 mmHg according to the TonoVet (R) and 14.95 +/- 2.92 mmHg according to the Tono-Pen Vet (R). There was no effect of sex, age, or eye side (right vs. left) on the results obtained with either the TonoVet (R) or the Tono-Pen Vet (R). The mean IOP obtained with the rebound tonometer was 2-3 mmHg higher than that measured with the applanation tonometer. The reference data obtained in the present study may assist in diagnostic testing for ophthalmic diseases in Turkish Shepherd Dogs and may promote further studies in this area.en_US
dc.language.isoengen_US
dc.publisherPolish Soc Veterinary Sciences Editorial Officeen_US
dc.identifier.doi10.21521/mw.6024
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectapplanation tonometryen_US
dc.subjectrebound tonometryen_US
dc.subjectdogen_US
dc.subjecteyeen_US
dc.subjectintraocular pressureen_US
dc.subjectCentral Corneal Thicknessen_US
dc.subjectOphthalmic Diagnostic-Testsen_US
dc.subjectPupil Diameteren_US
dc.subjectKangal Dogsen_US
dc.subjectHealthy Dogsen_US
dc.subjectMorphological-Characteristicsen_US
dc.subjectReference Valuesen_US
dc.subjectTear Productionen_US
dc.subjectCanine Eyesen_US
dc.subjectHydrochlorideen_US
dc.titleMeasurement of intraocular pressure in clinically normal Turkish Shepherd Dogs with the rebound tonometer (TonoVet (R)) and the applanation tonometer (Tono-Pen Vet (R))en_US
dc.typearticleen_US
dc.relation.ispartofMedycyna Weterynaryjna-Veterinary Medicine-Science and Practiceen_US
dc.departmentFakülteler, Veteriner Fakültesi, Klinik Bilimler Bölümü, Cerrahi Ana Bilim Dalıen_US
dc.identifier.volume74en_US
dc.identifier.issue9en_US
dc.identifier.startpage568en_US
dc.identifier.endpage573en_US
dc.institutionauthorKılıç, Servet
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid55316940600
dc.authorscopusid57202440441
dc.authorscopusid56154634600
dc.authorscopusid6603924496
dc.authorscopusid7006243697
dc.authorwosidKilic, Servet/ABA-3409-2020
dc.identifier.wosWOS:000442755200003en_US
dc.identifier.scopus2-s2.0-85054822766en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster