Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorMutlu, Harun
dc.contributor.authorPolat, Abdulkadir
dc.contributor.authorÇetin, Mehmet Ümit
dc.contributor.authorMutlu, Serhat
dc.contributor.authorDemir, Teyfik
dc.contributor.authorParmaksizoglu, Atilla Sancar
dc.date.accessioned2022-05-11T14:36:16Z
dc.date.available2022-05-11T14:36:16Z
dc.date.issued2022
dc.identifier.issn1413-7852
dc.identifier.issn1809-4406
dc.identifier.urihttps://doi.org/10.1590/1413-785220223001e248473
dc.identifier.urihttps://hdl.handle.net/20.500.11776/8428
dc.description.abstractIntroduction: We compared the mechanical properties of two fixation techniques for the treatment of extra-articular distal third humeral fractures. Materials and Methods: Two groups were created from twenty-four humeri. Group 1 was instrumented using a new, precontoured, 8-hole (3.5-mm-diameter) locking compression plate (LCP) placed anterolaterally. Group 2 was instrumented using an 8-hole (3.5-mm-diameter) precontoured posterolateral LCP plate placed on the distal humerus. Four-point bending tests and torsion tests were performed until the specimens broke. Results: The four-point bending stiffness test showed that the stiffness of anterolaterally fixed humeri was significantly higher than that of posterolaterally fixed humeri (p<0.05). Torsion testing revealed that posterolateral fixation was associated with better yield strength (p<0.05), but the torsional stiffness did not differ significantly between the two plates (p>0.05). Conclusions: The anterolateral plate exhibited higher bending stiffness and torsional yield strength than the posterolateral plate. Anterolateral plate fixation can thus be used to manage extra-articular distal humeral fractures. Multiaxial locking screws ensure rigid fixation, allow early elbow motion without olecranon fossa impingement, and prevent iatrogenic injury of the triceps muscle. Level of Evidence I, Therapeutic Studies Investigating the Results of Treatment.en_US
dc.language.isoengen_US
dc.publisherAtha Comunicacao & Editoraen_US
dc.identifier.doi10.1590/1413-785220223001e248473
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFracture Fixationen_US
dc.subjectHumeral Fracturesen_US
dc.subjectFracture Fixation,Internalen_US
dc.subjectFixationen_US
dc.subject3rden_US
dc.titleA New Anatomical Plate for Extra-Articular Distal Humeral Fractures: Biomechanical Studyen_US
dc.typearticleen_US
dc.relation.ispartofActa Ortopedica Brasileiraen_US
dc.departmentFakülteler, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalıen_US
dc.authorid0000-0002-3224-7134
dc.identifier.volume30en_US
dc.identifier.issue1en_US
dc.institutionauthorÇetin, Mehmet Ümit
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorwosidPOLAT, Abdulkadir/AAE-7385-2022
dc.identifier.wosWOS:000752525100010en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster