dc.description.abstractCurrent study is aimed at making the most appropriate design considering the dynamic energy, exergy and economic analysis of Ground Source Heat Pumps (GSHP). The energy required to heat and to cool a 200 m(2) office in Istanbul is determined, and based on these data, the entering and leaving water and soil temperatures of horizontal Ground Heat Exchanger (GHE) are obtained numerically for a ten-year period with realistic boundary conditions using meteorological data. The results obtained from the numerical study are confirmed by GHE experimental setup built in Yildiz Technical University. The variations of COP, second-law efficiency and exergy destruction of each component of GSHP at both seasons of the first, fifth and tenth years are obtained for Radiant Wall Panel Unit (RW-PU), Floor Heating + Fan-Coil Unit (FH-FCU) and Radiator + Fan-Coil Unit (R-FCU) systems. At the end of the 10-year dynamic simulation period of the GSHP system, the average values of COP and second law efficiency for RW-PU, FHFCU and R-FCU are found as 4.01, 3.37, 3.01, and 39.29%, 38.04%, 36.63%, respectively. Furthermore, considering the initial investment and operational costs of RW-PU, FH-FCU and R-FCU systems integrated into the GSHP system, an objective function is defined as an optimization parameter. (C) 2020 Elsevier Ltd. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.identifier.doi10.1016/j.renene.2020.06.150
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGround source heat pumpen_US
dc.subjectRadiant wall panelen_US
dc.subjectGreen buildingen_US
dc.subjectExergy and economic analysisen_US
dc.subjectOptimizationen_US
dc.subjectCoupled Heaten_US
dc.subjectThermal Performanceen_US
dc.subjectExergoeconomic Evaluationen_US
dc.subjectNumerical-Simulationen_US
dc.subjectSensitivity-Analysisen_US
dc.subjectSystemen_US
dc.subjectExchangersen_US
dc.titleEnergy and exergy analysis and thermo-economic optimization of the ground source heat pump integrated with radiant wall panel and fan-coil unit with floor heating or radiatoren_US
dc.typearticleen_US
dc.relation.ispartofRenewable Energyen_US
dc.departmentFakülteler, Çorlu Mühendislik Fakültesi, Makine Mühendisliği Bölümüen_US
dc.authorid0000-0002-8843-8191
dc.identifier.volume160en_US
dc.identifier.startpage333en_US
dc.identifier.endpage349en_US
dc.institutionauthorKayacı, Nurullah
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid55645106500
dc.authorwosidKAYACI, NURULLAH/AAD-8565-2019
dc.identifier.wosWOS:000572886800001en_US
dc.identifier.scopus2-s2.0-85087871371en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster