Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorYener, Şuayb Çağrı
dc.contributor.authorYener, Tuba
dc.contributor.authorMutlu, Reşat
dc.date.accessioned2022-05-11T14:17:39Z
dc.date.available2022-05-11T14:17:39Z
dc.date.issued2018
dc.identifier.issn1388-6150
dc.identifier.issn1588-2926
dc.identifier.urihttps://doi.org/10.1007/s10973-018-7453-y
dc.identifier.urihttps://hdl.handle.net/20.500.11776/6433
dc.description13th Mediterranean Conference of Calorimetry and Thermal Analysis (Medicta) -- SEP 24-27, 2017 -- Loano, ITALYen_US
dc.description.abstractIn this paper, the current, voltage and temperature of the container of an electric current-activated/assisted sintering (ECAS) system are measured and recorded with respect to time during the sintering process. By post-processing of the recorded data, the power and thermal energy of the system container are calculated. Interpretation of the measured and post-processed data has provided a criterion: It has been found that the dissipated electrical power in quasi-steady state is almost equal to the power conducted from the container to the copper bars throughout the stiffs and the convection and radiation powers are negligible compared to the conducted power. Therefore, the container-stored thermal energy or the container surface temperature can be estimated from the dissipated electrical power with the values of the container heat capacitance and the stiff thermal resistances without the need for a temperature measurement equipment. If the thermal energy or the temperature required to make the samples has a known/required minimum value and if this amount of the thermal energy is provided to the sample, the sample production process can be stopped. In this study, for an actual implemented design, we suggest that ECAS current and voltages should be continuously measured in real time and the process is automatically terminated when the calculated steady-state container temperature becomes equal to the required container temperature. Therefore, a standard procedure for material production in ECAS system is provided to automate sample production and the performance of the produced samples is guaranteed.en_US
dc.description.sponsorshipItalian Assoc Calorimetry & Thermal Anal, Univ Genoa, Italian Chem Soc, Interdivis Grp Calorimetry & Thermal Anal, Netzsch, Mettler Toledo, Automation, Infineum, TA Instruments, Noberascoen_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.identifier.doi10.1007/s10973-018-7453-y
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectElectric current-activated sinteringen_US
dc.subjectMeasurement systemen_US
dc.subjectThermal analysisen_US
dc.subjectProcess controlen_US
dc.subjectThermal-Analysisen_US
dc.subjectFielden_US
dc.subjectDischargeen_US
dc.subjectPowderen_US
dc.subjectModelen_US
dc.subjectConsolidationen_US
dc.subjectCompositesen_US
dc.subjectCompactionen_US
dc.titleA process control method for the electric current-activated/assisted sintering system based on the container-consumed power and temperature estimationen_US
dc.typeproceedingPaperen_US
dc.relation.ispartofJournal of Thermal Analysis and Calorimetryen_US
dc.departmentFakülteler, Çorlu Mühendislik Fakültesi, Elektronik ve Haberleşme Mühendisliği Bölümüen_US
dc.identifier.volume134en_US
dc.identifier.issue2en_US
dc.identifier.startpage1243en_US
dc.identifier.endpage1252en_US
dc.institutionauthorMutlu, Reşat
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.authorscopusid35410587000
dc.authorscopusid36678524100
dc.authorscopusid36515307500
dc.authorwosidMutlu, Resat/ABA-5309-2020
dc.identifier.wosWOS:000450801000038en_US
dc.identifier.scopus2-s2.0-85048086637en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster