dc.description.abstractAmaç: Tek parçalı ve 3 parçalı hidrofobik akrilik göz içi lensi (GİL) implante edilmiş hastalarda, siklopentolat hidroklorür (HCI) ve pilokarpin HCI’nin ön kamera derinliğine (ÖKD) etkisinin karşılaştırılması. Gereç ve Yöntem: Komplikasyonsuz saydam kornea kesili fakoemülsifikasyon ve GİL implantasyonu yapılmış 19 hastanın 19 gözü değerlendirildi. Hastaların 9’una (grup 1) tek parçalı (AcrySof SA60AT, Alcon) ve 10’una da (grup 2) 3 parçalı (AcrySof MA60BM, Alcon) katlanabilir, hidrofobik akrilik GİL implante edilmişti. Hastaların opere edilen gözlerinin ÖKD’ leri üç gün arayla, sırasıyla pilokarpin HCI %2 ve siklopentolat HCI %1 damlatıldıktan sonra T2 ağırlıklı manyetik rezonans görüntüleri kullanılarak aksiyel ve sagittal planda hesaplandı. Cerrahi ile manyetik rezonans görüntüleme arasındaki ortalama süre grup 1’de 16,1, grup 2’de 13.7 aydı. Wilcoxin ve Mann-Whitney U testleri ile grup içi ve gruplar arası kıyaslamalar yapıldı. Bulgular: Pilokarpin HCI sonrası ortalama ÖKD, grup 1 de 3,67 ± 0,39 mm ve grup 2’de 4,06 ± 0,24 mm idi (p=0,35). Siklopentolat HCI sonrası ÖKD, grup 1’de 3,70±0,37 mm ve grup 2’de 4,01 ± 0,20 mm idi (p=0,53). Pilokarpin HCI ve siklopentolat HCI sonrası ÖKD arasındaki ortalama fark, grup 1 ve grup 2’de, sırasıyla 0,027±0,087 mm ve -0,045±0,10 mm idi (p>0,05). Sonuç: Fakoemülsifikasyon ve GİL implantasyonu sonrası uzun dönemde siklopentolat HCI ve pilokarpin HCI, tek parçalı ve üç parçalı hidrofobik akrilik GİL’de anlamlı bir aksiyel harekete neden olmamaktadır.en_US
dc.description.abstractAim: To compare the effect of cyclopentolate hydrochloride (HCI) and pilocarpine HCI on anterior chamber depth (ACD) between single-piece and three-piece hydrophobic acrylic intraocular lens (IOL) after uneventful phacoemulsification using magnetic resonance imaging. Material and Method: Nineteen eyes of 19 patients who had uneventful sutureless clear corneal phacoemulsification with IOL implantation were included in the study. Nine eyes (group 1) had single-piece (AcrySof SA60AT, Alcon) and 10 eyes (group 2) had three-piece (AcrySof MA60BM, Alcon) foldable hydrophobic acrylic IOL. ACD was measured in the axial and sagittal T2 weighted magnetic resonance images after 2% pilocarpine HCI installation. Three days later, the same procedure was repeated after 1% cyclopentolate HCI installation. The average time interval between surgery and MR imaging was 16.1±0.9 months in group 1 and 13.7±0.8 months in group 2. Statistical analysis were performed with the Mann-Whitney U test between groups and the Wilcoxon signed rank test within them. Results: The average ACD after pilocarpine HCI instillation was 3.67±0.39 mm and 4.06 ± 0.24 mm in group 1 and group 2, respectively (p=0.35). The average ACD after cyclopentolate HCI instillation was 3.70±0.37 mm and 4.01±0.20 mm in group 1 and group 2, respectively (p=0.53). The difference between the average ACD after pilocarpine HCI and cyclopentolate HCI instillations were 0.027±0.087 mm and -0.045 ± 0.10 mm in group 1 and group 2, respectively (p>0.05). Conclusion: Pilocarpine HCI and cyclopentolate HCI do not cause a significant axial shift on single-piece and three-piece hydrophobic acrylic IOL in the late period after phacoemulsification and IOL implantation.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectGöz Hastalıklarıen_US
dc.titlePsödofakik gözlerde pilokarpinin uyardığı akomodasyonun ön kamera derinliğine etkisinin manyetik rezonans görüntüleri kullanılarak değerlendirilmesien_US
dc.title.alternativeThe evaluation of the effect of pilocarpine induced accomodation on anterior chamber depth in pseudophakic eyes using magnetic resonance imagingen_US
dc.typearticleen_US
dc.relation.ispartofMN Oftalmolojien_US
dc.departmentFakülteler, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalıen_US
dc.departmentFakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyoloji Ana Bilim Dalıen_US
dc.identifier.volume18en_US
dc.identifier.issue4en_US
dc.identifier.startpage224en_US
dc.identifier.endpage229en_US
dc.institutionauthorGönen, Tansu
dc.institutionauthorGönen, Korcan Aysun
dc.institutionauthorHorozoğlu, Fatih
dc.institutionauthorKeskinbora, H. Kadircan
dc.institutionauthorYaşar, Mustafa
dc.institutionauthorSever, Özkan
dc.identifier.trdizinidTVRNeE1UZ3pNdz09en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster