Ara
Toplam kayıt 59, listelenen: 51-59
Ultrasensitive determination of cadherin-like protein 22 with a label-free electrochemical immunosensor using brush type poly(thiophene-g-glycidylmethacrylate) modified disposable ITO electrode
(Elsevier Science Bv, 2019)
A label-free immunosensor for the determination of Cadherin-like protein 22 (CDH 22) was successfully developed by using poly(thiophene-g-glycidyl methacrylate) (PT-GMA) brush type polymer modified disposable ITO electrode. ...
A sensitive and disposable electrochemical immunosensor for detection of SOX2, a biomarker of cancer
(Elsevier Science Bv, 2017)
A novel, sensitive, disposable indium tin oxide (ITO)-based electrochemical immunosensor was developed firstly for simple, rapid determination of Sex-determining region Y-box 2 (SOX2). SOX2 is a cancer biomarker and used ...
An impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applications
(Academic Press Inc Elsevier Science, 2018)
In this study, we fabricated a sensitive and label-free impedimetric immunosensor based on 6-phosphonohexanoic acid (PHA) modified ITO electrode for detection of interleukin-8 (IL-8) in human serum and saliva. PHA was first ...
A novel silanization agent based single used biosensing system: Detection of C-reactive protein as a potential Alzheimer's disease blood biomarker
(Elsevier Science Bv, 2018)
This paper illustrates a new and sensitive electrochemical immunosensor for the analysis of C-reactive protein. Indium Tin Oxide (ITO) disposable sheets were modified by using 3-cyanopropyltrimethoxysilane (CPTMS) ...
Determination of C-reactive protein by PAMAM decorated ITO based disposable biosensing system: A new immunosensor design from an old molecule
(Elsevier Science Bv, 2018)
This paper demonstrates a new and sensitive electrochemical immunosensor for the analysis of C-reactive protein, an important marker of inflammation. Indium Tin Oxide (ITO) disposable sheets were modified by using ...
Cerebrospinal fluid levels of alpha-synuclein measured using a poly-glutamic acid-modified gold nanoparticle-doped disposable neuro-biosensor system
(Royal Soc Chemistry, 2019)
Alpha-synuclein (SYN) is a prominent key protein in Parkinson-type dementia. Measurement of the amount of this protein found in the cerebrospinal fluid (CSF) using precise techniques may help in the diagnosis and prognosis ...
A new methodology for the determination of enzyme activity based on carbon nanotubes and glucose oxidase
(Elsevier, 2015)
In this research, a novel enzyme activity analysis methodology is introduced as a new perspective for this area. The activity of elastase enzyme, which is a digestive enzyme mostly of found in the digestive system of ...
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
(Elsevier B.V., 2019)
A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ...
A Simple and Low-Cost Electrochemical Immunosensor for Ultrasensitive Determination of Calreticulin Biomarker in Human Serum
(Wiley-V C H Verlag Gmbh, 2023)
An early on time detection of breast cancer significantly affects the treatment process and outcome. Herein, a new label-free impedimetric biosensor is developed to determine the lowest change in the level of calreticulin ...