Konu "Biosensor" için PubMed İndeksli Yayın Koleksiyonu listeleme
Toplam kayıt 30, listelenen: 1-20
-
Amperometric Biosensor for Xanthine Determination Based On Fe3O4 Nanoparticles
(Slovensko Kemijsko Drustvo, 2014)An amperometric xanthine biosensor was developed based on the immobilization of xanthine oxidase (XO) into the Fe3O4 nanoparticles modified carbon paste. Electron transfer properties of unmodified and Fe3O4 nanoparticles ... -
Amperometric uric acid biosensor based on poly(vinylferrocene)-gelatin-carboxylated multiwalled carbon nanotube modified glassy carbon electrode
(Elsevier Science Bv, 2015)In this study, a new uric acid biosensor was constructed based on ferrocene containing polymer poly (vinylferrocene) (PVF), carboxylated multiwalled carbon nanotubes (c-MWCNT) and gelatin (GEL) modified glassy carbon ... -
Analysis of Tau-441 protein in clinical samples using rGO/AuNP nanocomposite-supported disposable impedimetric neuro-biosensing platform: Towards Alzheimer's disease detection
(Elsevier B.V., 2020)Changes in isoforms of Tau protein, which are critical for microtubule functioning, are accepted as being responsible for diseases characterized by dementia, in particular Alzheimer's disease (AD). In this comprehensive ... -
Applications of electrochemical immunosensors for early clinical diagnostics
(Elsevier Science Bv, 2015)Cancer and cardiovascular diseases are the major threats to global health. Hence, there is a growing demand for a range of portable, rapid and low cost biosensing devices for the detection of these diseases. Electrochemical ... -
Determination of C-reactive protein by PAMAM decorated ITO based disposable biosensing system: A new immunosensor design from an old molecule
(Elsevier Science Bv, 2018)This paper demonstrates a new and sensitive electrochemical immunosensor for the analysis of C-reactive protein, an important marker of inflammation. Indium Tin Oxide (ITO) disposable sheets were modified by using ... -
Development of an impedimetric aflatoxin M1 biosensor based on a DNA probe and gold nanoparticles
(Elsevier Advanced Technology, 2011)The present work describes the construction and application of a new DNA biosensor for detection of aflatoxin M1. In order to immobilize a thiol-modified single stranded DNA (ss-HSDNA) probe that specifically bound aflatoxin ... -
A disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serum
(Elsevier Advanced Technology, 2018)Label-free immunosensor based on tetra armed star-shaped poly(glycidylmethacrylate) (Star(PGMA)) modified disposable ITO electrode was developed for detection of p53 protein, an important colorectal cancer biomarker. This ... -
Electrochemical (bio)sensors based on carbon quantum dots, ionic liquid and gold nanoparticles for bisphenol
(Academic Press Inc Elsevier Science, 2023)Electrochemical (bio)sensors were developed for bisphenol A (BPA) determination. Screen printed carbon electrode (SPCE) was modified with ionic liquid 1- butyl-3-methylimidazolium tetrafluoroborate (IL), carbon quantum ... -
Electrochemical biosensor based on self-assembled monolayers modified with gold nanoparticles for detection of HER-3
(Elsevier Science Bv, 2014)We have developed a new immunological biosensor for ultrasensitive quantification of human epidermal growth factor receptor-3(HER-3). In order to construct the biosensor, the gold electrode surface was layered with, ... -
Electrochemical immunosensor based on chitosan/conductive carbon black composite modified disposable ITO electrode: An analytical platform for p53 detection
(Elsevier Advanced Technology, 2018)In this study, we fabricated a label-free electrochemical immunosensor for sensitive and selective detection of tumor marker p53. This immunosensor was based on chitosan/carbon black composite (Chitosan-CB) layer coated ... -
Fabrication of a highly sensitive disposable immunosensor based on indium tin oxide substrates for cancer biomarker detection
(Academic Press Inc Elsevier Science, 2014)Anti-HER-3 antibody was used for the first time in a disposable immunosensor based on indium tin oxide (ITO) substrate for HER-3 quantification. Anti-HER-3 was immobilized onto ITO substrate by 3-aminopropyl)triethoxysilane ... -
Graphene oxide based electrochemical label free immunosensor for rapid and highly sensitive determination of tumor marker HSP70
(Elsevier Science Bv, 2016)In this study, it is aimed to design a label free immunosensor for determination of HSP70 (heat shock protein 70). Glassy carbon electrode was used as a working electrode. Graphene oxide was covered on the working electrode ... -
A highly selective electrochemical immunosensor based on conductive carbon black and star PGMA polymer composite material for IL-8 biomarker detection in human serum and saliva
(Elsevier Advanced Technology, 2018)A new approach to enhance the electrochemical performance of biosensor was attempted by using Super P (c) carbon black/Star polymer composite material. In this study, we developed an electrochemical IL 8 biosensor by ... -
A highly sensitive immunosensor based on ITO thin films covered by a new semi-conductive conjugated polymer for the determination of TNF alpha in human saliva and serum samples
(Elsevier Advanced Technology, 2017)A novel, ultrasensitive impedimetric immunosensor was constructed for the detection of tumor necrosis factor alpha (TNF alpha) by using Poly(3-thiophene acetic acid) (P3), a conjugated polymer as an immobilization matrix. ... -
Impedimetric Detection of Calreticulin by a Disposable Immunosensor Modified with a Single-Walled Carbon Nanotube-Conducting Polymer Nanocomposite
(Amer Chemical Soc, 2022)A label-free impedimetric immunosensing system was constructed for ultrasensitive determination of the calreticulin (CALR) biological marker in human serum samples utilizing an electrochemical impedance spectroscopy analysis ... -
An impedimetric vascular endothelial growth factor biosensor-based PAMAM/cysteamine-modified gold electrode for monitoring of tumor growth
(Academic Press Inc Elsevier Science, 2012)In the present work, we have developed a new biosensor based on fourth-generation (G4) PAMAM dendrimers for the analysis of vascular endothelial growth factor (VEGF). First, the PAMAM dendrimers were covalently attached ... -
Introducing a new method for evaluation of the interaction between an antigen and an antibody: Single frequency impedance analysis for biosensing systems
(Elsevier Science Bv, 2014)This paper illustrates the application of an antibody, anti-parathyroid hormone (anti-PTH), as a bioreceptor in a biosensor system for the first time, and demonstrates how this biosensor can be used in parathyroid hormone ... -
A label-free electrochemical biosensor for direct detection of RACK 1 by using disposable, low-cost and reproducible ITO based electrode
(Elsevier Science Bv, 2018)In this study we designed an ultrasensitive electrochemical immunosensor for RACK 1 detection using 11-cyanoundecyltrimethoxysilane (11-CUTMS) as a immobilization matrix to immobilize biorecognition element. The used silane ... -
A nano-composite based regenerative neuro biosensor sensitive to Parkinsonism-associated protein DJ-1/Park7 in cerebrospinal fluid and saliva
(Elsevier B.V., 2021)In this study, we developed an electrochemical-based single-use neurobiosensor based on multiwalled carbon nanotube (MWCNT)-gold nanoparticle (AuNP) nanocomposite doped, 11-amino-1-undecanethiol (11-AUT)-modified polyethylene ... -
A new immobilization procedure for development of an electrochemical immunosensor for parathyroid hormone detection based on gold electrodes modified with 6-mercaptohexanol and silane
(Elsevier, 2015)Fabrication of a new electrochemical impedance-based biosensor for the analysis of parathyroid hormone (PTH), using self-assembled monolayers (SAMs) of mercaptohexanol and (3-Aminopropyl) triethoxysilane on gold electrodes, ...