dc.description.abstractIn this study, 4E (energy, exergy, exergoeconomic, and exergoenvironmental) analysis of an underfloor heating system integrated with the geothermal heat pump of a greenhouse with a usage area of 90 m(2) has been made. When the results of the 4E analysis applied to the system and its elements were examined, the energy efficiency of the heating system in the winter months has been determined to be 77.85% and the exergy efficiency 30.61%. According to the results of exergoeconomic analysis, the levelized energy cost of the system has been determined as 0.894 $/h, the unit exergy cost as 0.826 $/h, and the exergoeconomic factor value as 51.12%. According to the results of the exergoenvironmental analysis, the part-based environmental impact of the system was 0.0910 mPts/s, the environmental impact value due to exergy was 0.1823 mPts/s, and the exergoenvironmental factor value was 37.77%. In addition, the equivalent CO2 emission value that will occur if the heating requirement of the greenhouse is met with a natural gas boiler instead of a geothermal heat pump was investigated and a comparison was made between the two systems. Accordingly, it has been determined that the emission of 909.75 kg equivalent carbon dioxide to the environment will be prevented in the 4-month period, which is considered the heating season, by using the heat pump. As a result, the examined heating system has been evaluated as the effective system for heating the greenhouse, reducing energy consumption, and reducing emissions that cause environmental pollution.en_US
dc.language.isoengen_US
dc.publisherScientific And Technological Research Council Turkeyen_US
dc.identifier.doi10.55730/1300-011X.3040
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectGreenhouseen_US
dc.subjectenergy analysisen_US
dc.subjectexergy analysisen_US
dc.subjectexergoeconomic analysisen_US
dc.subjectexergoenvironmental analysisen_US
dc.subjectequivalent CO2 emissionen_US
dc.subjectThermal Comforten_US
dc.subjectExergy Analysisen_US
dc.subjectExergoenvironmental Analysisen_US
dc.subjectExergoeconomic Analysisen_US
dc.subjectPerformance Analysisen_US
dc.subjectCooling Systemsen_US
dc.subjectDrying Systemen_US
dc.subjectEnergyen_US
dc.subjectBuildingsen_US
dc.subjectFlooren_US
dc.title4E analysis of an underfloor heating system integrated to the geothermal heat pump for greenhouse heatingen_US
dc.typearticleen_US
dc.relation.ispartofTurkish Journal Of Agriculture And Forestryen_US
dc.departmentMeslek Yüksekokulları, Çorlu Meslek Yüksekokulu, Makine ve Metal Teknolojileri Bölümüen_US
dc.identifier.volume46en_US
dc.identifier.issue5en_US
dc.identifier.startpage762en_US
dc.identifier.endpage780en_US
dc.institutionauthorAkan, Ahmet Erhan
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.wosWOS:000891212600012en_US
dc.identifier.scopus2-s2.0-85140029579en_US
dc.identifier.trdizinid1141376en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster