A disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serum
(Elsevier Advanced Technology, 2018)
Label-free immunosensor based on tetra armed star-shaped poly(glycidylmethacrylate) (Star(PGMA)) modified disposable ITO electrode was developed for detection of p53 protein, an important colorectal cancer biomarker. This ...
A highly sensitive immunosensor based on ITO thin films covered by a new semi-conductive conjugated polymer for the determination of TNF alpha in human saliva and serum samples
(Elsevier Advanced Technology, 2017)
A novel, ultrasensitive impedimetric immunosensor was constructed for the detection of tumor necrosis factor alpha (TNF alpha) by using Poly(3-thiophene acetic acid) (P3), a conjugated polymer as an immobilization matrix. ...
Advances in electrochemical immunosensors
(Elsevier Academic Press Inc, 2019)
Immunosensors are compact tools on which antibody and antigen interactions are formed. The specific interaction between antibody and antigen is detected by using a transducer and an electrical signal is measured. This ...
Highly sensitive electrochemical immunosensor based on polythiophene polymer with densely populated carboxyl groups as immobilization matrix for detection of interleukin 1 beta in human serum and saliva
(Elsevier Science Sa, 2018)
A new impedimetric immunosensor was fabricated for detection of Interleukin 1 beta (IL-1 beta) by using semi-conductive poly(2-thiophen-3-yl-malonic acid) (P3-TMA) as an immobilization matrix material and anti-IL-1 beta ...
Ultrasensitive determination of cadherin-like protein 22 with a label-free electrochemical immunosensor using brush type poly(thiophene-g-glycidylmethacrylate) modified disposable ITO electrode
(Elsevier Science Bv, 2019)
A label-free immunosensor for the determination of Cadherin-like protein 22 (CDH 22) was successfully developed by using poly(thiophene-g-glycidyl methacrylate) (PT-GMA) brush type polymer modified disposable ITO electrode. ...
The development of an ultra-sensitive electrochemical immunosensor using a PPyr-NHS functionalized disposable ITO sheet for the detection of interleukin 6 in real human serums
(Royal Soc Chemistry, 2020)
A label-free impedimetric immunosensor based on a conjugated poly(pyrroleN-hydroxy succinimide) (PPyr-NHS) polymer covered disposable indium tin oxide electrode (ITO) was fabricated for the ultrasensitive determination of ...