An Effective Technique in Treatment of Femoral Neck Fractures - Ostheosynthesis under Double Fluoroscopic Guidance

dc.authorid0000-0001-7734-6438
dc.authorid0000-0002-1199-6320
dc.authorwosidçamur, savaş/AAF-5506-2020
dc.authorwosidTALMAC, MEHMET ALİ/AAL-3780-2020
dc.authorwosidGülenç, Barış/AAC-8539-2019
dc.contributor.authorGülenç, B.
dc.contributor.authorGünaydın, Burak
dc.contributor.authorÇamur, S.
dc.contributor.authorTalmac, M. A.
dc.contributor.authorGüler, V.
dc.contributor.authorKara, A.
dc.date.accessioned2022-05-11T14:36:14Z
dc.date.available2022-05-11T14:36:14Z
dc.date.issued2019
dc.departmentFakülteler, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalı
dc.description.abstractPURPOSE OF THE STUDY The most commonly used technique for fixation of the femoral neck fractures is percutaneous osteosynthesis with cannulated screw under fluoroscopy guidance. Osteosynthesis performed under single-fluoroscopic guidance requires continuous repositioning the fluoroscope to obtain biplane imaging. This study aimed to evaluate whether there is a statistically significant difference between the osteosynthesis procedures performed under guidance of single-fluoroscopy and double fluoroscopy with respect to radiation emission safety and treatment parameters for fixation of femoral neck fractures. MATERIAL AND METHODS This retrospective study included 35 patients operated for femoral neck fracture between December 2013 and October 2017. Osteosynthesis was performed in 21 of these patients using cannulated screw under guidance of single-fluoroscopy whereas other 14 patients underwent same type of osteosynthesis assisted by double-fluoroscopy. The parameters of these two groups such as duration of surgery preparation, duration of the surgery, duration of radiation exposure, collo-diaphyseal angle and Harris hip score values were recorded. RESULTS No significant difference was found between the groups regarding time for surgery preparation (p > 0.05). On the other hand, duration of surgery and overall duration of radiation exposure were found 14 (p < 0.05) and 15 (p < 0.05) minutes shorter in the double-fluoroscopy group, respectively. No significant difference was found between the groups in terms of collo-diaphyseal angle and Harris hip score values (p > 0.05). CONCLUSIONS Use of double-fluoroscopy significantly reduces time of surgical duration and also level of radiation exposure in surgery of femoral neck fractures.
dc.identifier.endpage275
dc.identifier.issn0001-5415
dc.identifier.issue4en_US
dc.identifier.pmid31524588
dc.identifier.startpage271
dc.identifier.urihttps://hdl.handle.net/20.500.11776/8415
dc.identifier.volume86
dc.identifier.wosWOS:000483007800005
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubMed
dc.institutionauthorGünaydın, Burak
dc.language.isoen
dc.publisherGalen Sro
dc.relation.ispartofActa Chirurgiae Orthopaedicae Et Traumatologiae Cechoslovaca
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectdouble fluoroscopy
dc.subjectfemoral neck fractures
dc.subjectradiation
dc.subjectosteosynthesis
dc.subjectcannulated screw
dc.subjectInternal-Fixation
dc.subjectScrew Fixation
dc.subjectRisk-Factors
dc.subjectOutcomes
dc.subjectAdults
dc.subjectHead
dc.titleAn Effective Technique in Treatment of Femoral Neck Fractures - Ostheosynthesis under Double Fluoroscopic Guidance
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
8415.pdf
Boyut:
184.52 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text