Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Dincer, Ali Riza" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Treatment of Leather Industry Wastewater Using Coagulation, Ultraviolet/Persulfate Processing and Nanofiltration for Water Recovery
    (Pleiades Publishing Inc, 2024) Dincer, Ali Riza; Cifci, Deniz Izlen; Karaca, Feriha
    This study investigated water recovery with the treatment of leather industry processes wastewater (washing, pickling, and degreasing units) using coagulation, ultraviolet/persulfate (UV/PS) treatment, and nanofiltration processes. Coagulation studies were carried out using alum as the coagulant, and the highest chemical oxygen demand (COD) removal efficiency was obtained at pH 7 for all the wastewater. The highest COD and total organic carbon (TOC) removal were 80.9 and 50.5% in the wastewater washing unit (S2O82-: 8 g/L, pH 7) and 76.5 and 96.1% in the wastewater degreasing unit (S2O82-: 16 g/L, pH 6) using UV/PS oxidation, respectively. High COD and TOC removal could not be achieved with UV/PS oxidation in the wastewater pickling unit. In the studies performed with NP030 nanofiltration membrane after UV/PS oxidation, the highest permeability and COD removal was achieved at pH 7 under 4 x 10(5) Pa pressure in wastewater washing and degreasing units. After 75 min of nanofiltration at pH 7 in washing and degreasing units, the total filtrate amount was 39.8 and 42.3 L/m(2) h, respectively. COD concentration in the wastewater washing unit decreased from 4434 to 138 mg/L, while it decreased from 5833 to 212 mg/L in the wastewater degreasing unit with coagulation, UV/PS processing, and nanofiltration. As a result, the treatment of leather industry wastewater through separate streams with coagulation, UV/PS, and nanofiltration, washing, and degreasing unit wastewater provides very high COD removal. Also, it has been shown impossible to treat the pickling unit wastewater by UV/PS oxidation.

| Tekirdağ Namık KemalÜniversitesi | Kütüphane | Açık Bilim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Namık Kemal Üniversitesi, Tekirdağ, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim