Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorSoyaslan, Devrim
dc.contributor.authorÇömlekçi, S.
dc.contributor.authorGöktepe, Özer
dc.date.accessioned2022-05-11T14:26:55Z
dc.date.available2022-05-11T14:26:55Z
dc.date.issued2010
dc.identifier.issn0040-5000
dc.identifier.urihttps://doi.org/10.1080/00405000902945360
dc.identifier.urihttps://hdl.handle.net/20.500.11776/6650
dc.description.abstractIn this study, electromagnetic shielding effectiveness of some weft-knitted structures is investigated. For this purpose, weft-knitted structures are produced using copper wire/cotton incorporated yarns. Conductive yarns are produced by yarn-folding machine. Four knitted constructions (plain knitting, weft in-laid plain knitting, 1X1 rib, and weft in-laid 1X1 rib) are formed into knitted structures with conductive yarns by using 7G flat knitting machine. Electromagnetic shielding values of test samples are determined by a coaxial test fixture relating to ASTM D4935 test standards. Measurements are made in the frequency range of 27 MHz-3 GHz. The effect of conductive content, stitch density and fabric construction parameters are investigated considering the electromagnetic shielding performance of weft-knitted structures. Test results show that weft-knitted structures investigated in this study have 10-40 dB shielding effectiveness under the frequency of 500 MHz.en_US
dc.description.sponsorshipBoard of Project of Suleyman Demirel UniversitySuleyman Demirel University [107-M-368]; Scientific and Technological Research Council of Turkey (TUBI TAK)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [1438-D-06]en_US
dc.description.sponsorshipThe authors appreciate the Board of Project of Suleyman Demirel University (Project No. 107-M-368) and the Scientific and Technological Research Council of Turkey (TUBI TAK, Project No. 1438-D-06) for supporting their study. They also thank to York EMC Services Ltd. for testing the shielding effectiveness tests.en_US
dc.language.isoengen_US
dc.publisherTaylor & Francis Ltden_US
dc.identifier.doi10.1080/00405000902945360
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectelectromagnetic shielding effectivenessen_US
dc.subjectASTM D4935en_US
dc.subjectelectromagnetic shielding fabricsen_US
dc.subjectweft-knitted structuresen_US
dc.subjectconductive yarnen_US
dc.subjectReinforced Polypropylene Compositesen_US
dc.subjectFabricsen_US
dc.titleDetermination of electromagnetic shielding performance of plain knitting and 1X1 rib structures with coaxial test fixture relating to ASTM D4935en_US
dc.typearticleen_US
dc.relation.ispartofJournal of the Textile Instituteen_US
dc.departmentFakülteler, Çorlu Mühendislik Fakültesi, Tekstil Mühendisliği Bölümüen_US
dc.authorid0000-0002-4849-9483
dc.authorid0000-0003-1389-6435
dc.identifier.volume101en_US
dc.identifier.issue10en_US
dc.identifier.startpage890en_US
dc.identifier.endpage897en_US
dc.institutionauthorGöktepe, Özer
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid36477846000
dc.authorscopusid56000080300
dc.authorscopusid6603904545
dc.authorwosidGÖKTEPE, ÖZER/ABA-5620-2020
dc.authorwosidSOYASLAN, DEVRİM DEMİRAY/AAP-9426-2021
dc.identifier.wosWOS:000281873200004en_US
dc.identifier.scopus2-s2.0-77956634053en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster