Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorGok, Caglar
dc.contributor.authorDevecioğlu, İsmail
dc.contributor.authorGüçlü, Burak
dc.date.accessioned2022-05-11T14:03:02Z
dc.date.available2022-05-11T14:03:02Z
dc.date.issued2022
dc.identifier.issn0148-0731
dc.identifier.issn1528-8951
dc.identifier.urihttps://doi.org/10.1115/1.4052225
dc.identifier.urihttps://hdl.handle.net/20.500.11776/4583
dc.description.abstractThe mechanical impedance of intact and epidermis-peeled rat glabrous skin was studied at two sites (digit and sole) and at two frequencies (40 Hz and 250 Hz). The thicknesses of skin layers at the corresponding regions were measured histologically from intact- and peeled-skin samples in every subject. Compared to intact sole skin, digital rat skin has thicker layers and higher mechanical resistance, and it is less stiff. The resistance of the skin significantly decreased after epidermal peeling at both the digit and the sole. Furthermore, peeling caused the reactance to become positive due to inertial effects. As the frequency was increased from 40 to 250 Hz, the resistance and stiffness also increased for the intact skin, while the peeled skin showed less frictional (i.e., resistance) but more inertial (i.e., positive reactance) effects. We estimated the mechanical properties of epidermis and dermis with lumped-element models developed for both intact and peeled conditions. The models predicted that dermis has higher mass, lower stiffness, and lower resistance compared to epidermis, similar to the experimental impedance results obtained in the peeled condition which consisted mostly of dermis. The overall impedance was simulated more successfully at 40 Hz. When both frequencies are considered, the models produced consistent results for resistance in both conditions. The results imply that most of the model parameters should be frequency-dependent and suggest that mechanical properties of epidermis can be related to its thickness. These findings may help in designing artificial skin for neuroprosthetic limbs.en_US
dc.description.sponsorshipBogazici University Research FundBogazici University [10XP1]; Society for Neuroscience Abstracts [224.13]en_US
dc.description.sponsorshipThis study was supported by Bogazici University Research Fund (BAP No. 10XP1) granted to Professor Guclu. Preliminary results were previously published as an abstract (C. Gok and B. Guclu (2017) Effects of morphometric variables and epidermal peeling on the mechanical impedance of rat glabrous skin, Society for Neuroscience Abstracts, 43, Program No. 224.13). The authors report no conflicts of interest.en_US
dc.language.isoengen_US
dc.publisherAsmeen_US
dc.identifier.doi10.1115/1.4052225
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectglabrous skinen_US
dc.subjectraten_US
dc.subjectvibrationen_US
dc.subjectmechanical impedanceen_US
dc.subjectstratum corneumen_US
dc.subjectviable epidermisen_US
dc.subjectdermisen_US
dc.subjectneuroprostheticsen_US
dc.subjectIn-Vivoen_US
dc.subjectMeissner Corpusclesen_US
dc.subjectStratum-Corneumen_US
dc.subjectTactileen_US
dc.subjectBehavioren_US
dc.subjectResponsesen_US
dc.subjectModelsen_US
dc.subjectBiomechanicsen_US
dc.subjectCompressionen_US
dc.subjectSensitivityen_US
dc.titleMechanical Impedance of Rat Glabrous Skin and Its Relation With Skin Morphometryen_US
dc.typearticleen_US
dc.relation.ispartofJournal Of Biomechanical Engineering-Transactions Of The Asmeen_US
dc.departmentFakülteler, Çorlu Mühendislik Fakültesi, Biyomedikal Mühendisliği Bölümüen_US
dc.authorid0000-0003-4119-617X
dc.identifier.volume144en_US
dc.identifier.issue2en_US
dc.institutionauthorDevecioğlu, İsmail
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorwosidDEVECIOGLU, ISMAIL/H-4523-2018
dc.identifier.wosWOS:000732721400005en_US
dc.identifier.pmid34423811en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster