Ara
Toplam kayıt 27, listelenen: 21-27
A highly sensitive immunosensor based on ITO thin films covered by a new semi-conductive conjugated polymer for the determination of TNF alpha in human saliva and serum samples
(Elsevier Advanced Technology, 2017)
A novel, ultrasensitive impedimetric immunosensor was constructed for the detection of tumor necrosis factor alpha (TNF alpha) by using Poly(3-thiophene acetic acid) (P3), a conjugated polymer as an immobilization matrix. ...
Highly sensitive electrochemical immunosensor based on polythiophene polymer with densely populated carboxyl groups as immobilization matrix for detection of interleukin 1 beta in human serum and saliva
(Elsevier Science Sa, 2018)
A new impedimetric immunosensor was fabricated for detection of Interleukin 1 beta (IL-1 beta) by using semi-conductive poly(2-thiophen-3-yl-malonic acid) (P3-TMA) as an immobilization matrix material and anti-IL-1 beta ...
A disposable and ultrasensitive ITO based biosensor modified by 6-phosphonohexanoic acid for electrochemical sensing of IL-1 beta in human serum and saliva
(Elsevier Science Bv, 2018)
In this study, we constructed a new and sensitive ITO based electrochemical immunosensor for detection of interleukin 1 beta(IL-1 beta), a cancer biomarker found in serum and saliva. 6-phosphonohexanoic acid (PHA) was used ...
Indium tin oxide (ITO): A promising material in biosensing technology
(Elsevier Sci Ltd, 2017)
This review focuses on the recent advances in indium tin oxide (ITO) based biosensors and sensors, which are utilized in different areas such as clinical diagnosis, food analysis and environmental monitoring. The purpose ...
A sensitive and disposable electrochemical immunosensor for detection of SOX2, a biomarker of cancer
(Elsevier Science Bv, 2017)
A novel, sensitive, disposable indium tin oxide (ITO)-based electrochemical immunosensor was developed firstly for simple, rapid determination of Sex-determining region Y-box 2 (SOX2). SOX2 is a cancer biomarker and used ...
An impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applications
(Academic Press Inc Elsevier Science, 2018)
In this study, we fabricated a sensitive and label-free impedimetric immunosensor based on 6-phosphonohexanoic acid (PHA) modified ITO electrode for detection of interleukin-8 (IL-8) in human serum and saliva. PHA was first ...
Nörodejeneratif Hastalıkların Erken Teşhisi İçin Elektrokimyasal Biyosensör Sistemleri
(Namık Kemal Üniversitesi, 2016)
Gelişmiş sanayi toplumlarında yaşam sürecinin uzaması yeni sorunları da beraberinde getirmektedir. İn;lamasyon, ilerleyen yaş ile birlikte görülen ölüm oranı en yüksek hastalıklar olan Alzheimer, ...