Ara
Toplam kayıt 41, listelenen: 31-40
A highly selective electrochemical immunosensor based on conductive carbon black and star PGMA polymer composite material for IL-8 biomarker detection in human serum and saliva
(Elsevier Advanced Technology, 2018)
A new approach to enhance the electrochemical performance of biosensor was attempted by using Super P (c) carbon black/Star polymer composite material. In this study, we developed an electrochemical IL 8 biosensor by ...
Electrochemical immunosensor based on chitosan/conductive carbon black composite modified disposable ITO electrode: An analytical platform for p53 detection
(Elsevier Advanced Technology, 2018)
In this study, we fabricated a label-free electrochemical immunosensor for sensitive and selective detection of tumor marker p53. This immunosensor was based on chitosan/carbon black composite (Chitosan-CB) layer coated ...
A disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serum
(Elsevier Advanced Technology, 2018)
Label-free immunosensor based on tetra armed star-shaped poly(glycidylmethacrylate) (Star(PGMA)) modified disposable ITO electrode was developed for detection of p53 protein, an important colorectal cancer biomarker. This ...
A highly sensitive immunosensor based on ITO thin films covered by a new semi-conductive conjugated polymer for the determination of TNF alpha in human saliva and serum samples
(Elsevier Advanced Technology, 2017)
A novel, ultrasensitive impedimetric immunosensor was constructed for the detection of tumor necrosis factor alpha (TNF alpha) by using Poly(3-thiophene acetic acid) (P3), a conjugated polymer as an immobilization matrix. ...
Ultrasensitive determination of cadherin-like protein 22 with a label-free electrochemical immunosensor using brush type poly(thiophene-g-glycidylmethacrylate) modified disposable ITO electrode
(Elsevier Science Bv, 2019)
A label-free immunosensor for the determination of Cadherin-like protein 22 (CDH 22) was successfully developed by using poly(thiophene-g-glycidyl methacrylate) (PT-GMA) brush type polymer modified disposable ITO electrode. ...
A novel silanization agent based single used biosensing system: Detection of C-reactive protein as a potential Alzheimer's disease blood biomarker
(Elsevier Science Bv, 2018)
This paper illustrates a new and sensitive electrochemical immunosensor for the analysis of C-reactive protein. Indium Tin Oxide (ITO) disposable sheets were modified by using 3-cyanopropyltrimethoxysilane (CPTMS) ...
Determination of C-reactive protein by PAMAM decorated ITO based disposable biosensing system: A new immunosensor design from an old molecule
(Elsevier Science Bv, 2018)
This paper demonstrates a new and sensitive electrochemical immunosensor for the analysis of C-reactive protein, an important marker of inflammation. Indium Tin Oxide (ITO) disposable sheets were modified by using ...
Impedimetric Detection of Calreticulin by a Disposable Immunosensor Modified with a Single-Walled Carbon Nanotube-Conducting Polymer Nanocomposite
(Amer Chemical Soc, 2022)
A label-free impedimetric immunosensing system was constructed for ultrasensitive determination of the calreticulin (CALR) biological marker in human serum samples utilizing an electrochemical impedance spectroscopy analysis ...
Metal nanoparticles for miRNA detection
(Marmara Univ, 2022)
Biosensing can be used for analysis, diagnosis and determination of biological target structures. But the improvement of sensitivity and sensing threshold is an important problem to overcome. It is possible to solve this ...
Electrochemical (bio)sensors based on carbon quantum dots, ionic liquid and gold nanoparticles for bisphenol
(Academic Press Inc Elsevier Science, 2023)
Electrochemical (bio)sensors were developed for bisphenol A (BPA) determination. Screen printed carbon electrode (SPCE) was modified with ionic liquid 1- butyl-3-methylimidazolium tetrafluoroborate (IL), carbon quantum ...