Ara
Toplam kayıt 30, listelenen: 21-30
Analysis of Tau-441 protein in clinical samples using rGO/AuNP nanocomposite-supported disposable impedimetric neuro-biosensing platform: Towards Alzheimer's disease detection
(Elsevier B.V., 2020)
Changes in isoforms of Tau protein, which are critical for microtubule functioning, are accepted as being responsible for diseases characterized by dementia, in particular Alzheimer's disease (AD). In this comprehensive ...
Ultrasensitive detection of interleukin 1? using 3-phosphonopropionic acid modified FTO surface as an effective platform for disposable biosensor fabrication
(Elsevier B.V., 2021)
In this study, we utilized a carboxyalkylphosphonic acid covered fluorine doped tin oxide (FTO) as an electrode material for fabrication of Interleukin 1? (IL-1?) immunosensor. For this aim, anti-IL-1? antibodies were ...
Ultrasensitive and Selective Impedimetric Determination of Prostate Specific Membrane Antigen Based on Di-Succinimide Functionalized Polythiophene Covered Cost-Effective Indium Tin Oxide
(John Wiley and Sons Inc, 2021)
A new and ultrasensitive impedimetric biosensor fabricated by using conjugated di-succinimide substituted polythiophene (P(ThidiSuc)) polymer modified indium tin oxide electrode is developed for the first time to detect ...
A Highly Selective Poly(thiophene)-graft-Poly(methacrylamide) Polymer Modified ITO Electrode for Neuron Specific Enolase Detection in Human Serum
(Wiley-VCH Verlag, 2019)
In this study, an impedimetric immunosensor based on polymer poly(thiophene)-graft-poly(methacrylamide) polymer (P(Thi-g-MAm)) modified indium tin oxide (ITO) electrode is developed for the detection of the Neuron Specific ...
A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode
(Elsevier B.V., 2020)
A new flexible biosensor based on conjugated polymer functionalized indium tin oxide (ITO) sheet was fabricated for Receptor for Activated C Kinase 1 (RACK 1) determination. Poly(3-thiophene acetic acid) (P(Thi-Ac)) was ...
An impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applications
(Academic Press Inc Elsevier Science, 2018)
In this study, we fabricated a sensitive and label-free impedimetric immunosensor based on 6-phosphonohexanoic acid (PHA) modified ITO electrode for detection of interleukin-8 (IL-8) in human serum and saliva. PHA was first ...
Degradation of antibiotic ampicillin on boron-doped diamond anode using the combined electrochemical oxidation - Sodium persulfate process
(Academic Press, 2018)
In this work, the electrochemical oxidation of antibiotic ampicillin (AMP) on a boron-doped diamond anode in the presence of sodium persulfate (SPS) was investigated (EO/SPS process). Experiments were conducted at AMP ...
A new methodology for the determination of enzyme activity based on carbon nanotubes and glucose oxidase
(Elsevier, 2015)
In this research, a novel enzyme activity analysis methodology is introduced as a new perspective for this area. The activity of elastase enzyme, which is a digestive enzyme mostly of found in the digestive system of ...
Capacitance behaviors of EDOT and pyrrole copolymer, and equivalent circuit model
(Taylor and Francis Ltd., 2018)
In this paper, a copolymer of 3,4-Ethylenedioxythiophene (EDOT) and pyrrole (Py) were electrochemically synthesised on glassy carbon electrode by cyclic voltammetry (CV). The modified electrodes were characterised by CV, ...
A comparison between LP(GMA) and CLP(GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1a
(Elsevier B.V., 2019)
A comparative study was made by using two matrices (Linear poly(glycidyl methacrylate) (GMA) polymer (LP(GMA)) and carbon black-polyvinylidene fluoride (PVDF)-LP(GMA) composite CLP(GMA)) as immobilization platforms for ...