Ultrasensitive and Selective Impedimetric Determination of Prostate Specific Membrane Antigen Based on Di-Succinimide Functionalized Polythiophene Covered Cost-Effective Indium Tin Oxide
Özet
A new and ultrasensitive impedimetric biosensor fabricated by using conjugated di-succinimide substituted polythiophene (P(ThidiSuc)) polymer modified indium tin oxide electrode is developed for the first time to detect the prostate specific membrane antigen (PSMA). The polymer P(Thi-diSuc) is synthesized by using a simple way and used in the fabrication of the proposed biosensor. The synthesized polymer contains di-succinimide groups, which offers covalent immobilization of PSMA specific antibodies. The developed strategy shortens the biosensor fabrication steps, because these active groups bind covalently to the amino ends of PSMA specific antibodies and this reaction does not require any crosslinking agent. Various characterization studies like impedimetric and voltammetric measurements, and morphological analyses are utilized to confirm the successful development of the biosensor. Under optimum conditions, the biosensing ability of the PSMA determination has a wide linear determination range from 0.015 to 14.4 pg mL?1, as well as a low limit of detection of 6.4 fg mL?1 and a high sensitivity of 1.36 kohm pg?1 mL cm?2. Furthermore, the proposed biosensor is able to measure the PSMA antigen in real human serums, which offers that it is a simple, low-cost, and sensitive tool with excellent potential for application in the quantification of PSMA. © 2021 Wiley-VCH GmbH
Cilt
21Sayı
10İlgili Öğeler
Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.
-
Electrochemical Immunosensor for Detection of CCR4 Cancer Biomarker in Human Serum: An Alternative Strategy for Modification of Disposable ITO Electrode
Aydın, Elif Burcu; Aydın, Muhammet; Sezgintürk, Mustafa Kemal (Wiley-VCH Verlag, 2021)Herein, a new strategy for the fabrication of a sensitive immunosensor capable of determination of CC Chemokine receptor 4 (CCR4) in complex serum samples is developed through the polymer modification on the disposable ... -
An epoxysilane modified indium tin oxide electrode for the determination of PAK 2: Application in human serum samples
Yılmaz, Nergiz; Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal (Elsevier B.V., 2019)In this study, a sensitive immunosensor was developed for the first time for p21-activated kinase 2 (PAK 2) detection. In the design of the immunosensor, 3-glycidoxypropyltrimethoxysilane (GPTMS) was utilized as an ITO ... -
A sensitive and selective approach for detection of IL 1? cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
Aydın, Muhammet (Elsevier Ltd, 2019)A highly sensitive and label-free electrochemical immunosensor for sensitive detection of interleukin 1? cancer biomarker was described by using epoxy-substituted polythiophene polymer modified disposable indium tin oxide ...